Advanced Search
    DONG An, SHI Li-bo. Analysis on Radiographic Testing for Branch Connection in Some NPP[J]. Nondestructive Testing, 2014, 36(1): 27-31.
    Citation: DONG An, SHI Li-bo. Analysis on Radiographic Testing for Branch Connection in Some NPP[J]. Nondestructive Testing, 2014, 36(1): 27-31.

    Analysis on Radiographic Testing for Branch Connection in Some NPP

    More Information
    • Received Date: January 26, 2013
    • On construction of certain NPP, some films cannot be positioned inside the branch subjected to examination. This situation was caused by various reasons and deviate from codes. Designing improvement, construction management and RT techniques were discussed based on RCC-M requirements. A 3D model with radiation parameters was established by Solidworks software. RT technique for branch connection, using double wall exposure with single viewing, was quantitatively analyzed by this model. Through this model optimized suggestions were proposed for radiographic testing for branch connection.
    • [1]
      董吉原.等径三通安装焊缝的射线检验[J].无损检测,2008,30(1):67-68.
      [2]
      李衍.压力容器无损检测——射线检测技术[J].无损检测,2004,26(1):30-36.
      [3]
      李衍.特型接头对接焊缝的射线透照技术[J].中国锅炉压力容器安全,2000,22(5):46-49.
      [4]
      庄文栋.厚壁焊缝三通角焊缝射线照相工艺[J].无损检测,1996,18(11):315-316.
      [5]
      强天鹏.射线检验[M].北京:中国劳动社会保障出版社,2007.
      [6]
      实威科技.Solidworks原厂教育训练手册[M].北京:清华大学出版社,2006.