Advanced Search
    WANG Zeng-Yong, SUN Chao-Ming, LI Jian-Wen, LIU Zun-Wei. Lamb Wave Testing of TaW Alloy Plates[J]. Nondestructive Testing, 2009, 31(9): 689-690.
    Citation: WANG Zeng-Yong, SUN Chao-Ming, LI Jian-Wen, LIU Zun-Wei. Lamb Wave Testing of TaW Alloy Plates[J]. Nondestructive Testing, 2009, 31(9): 689-690.

    Lamb Wave Testing of TaW Alloy Plates

    More Information
    • Received Date: November 11, 2008
    • Aiming to evaluate inner quality of TaW alloy plates about 1.6 mm(thickness)×80 mm(width), using the manufactured 1.25P15×20 38° type ultrasonic transducer, the testing experiment has been actualized by lamb wave method. Its frequency was 1.25 MHz, an angle of incidence was 38°, and the size of wafer was 15 mm×20 mm. The sensitivity test results indicated that not only the defect about  0.4 mm in plate could be finded using this transducer, but also between the hole diameter and lamb wave amptitude was shown linear relation. It fulfilled quality demand of production.
    • [1]
      张廷杰, 刘建章, 丁旭, 等.Ta-12W 合金的高温拉伸特性[J].稀有金属材料与工程,1999,28(6):345-348.
      [2]
      GB/T 8651—2002 金属板材超声板波探伤方法[S].
      [3]
      徐可北.金属薄板兰姆波检测技术[J].无损检测,1999,21(10):461-465.
      [4]
      尚世同, 尚瑜娟.超声板波法在变厚度板检测中的应用[J].无损检测,1998,20(3):80-82,85.
      [5]
      许可北, 张建合.复合材料层板泄漏兰姆波检测技术研究[J].无损检测,1999,21(11):505-508,511.

    Catalog

      Article views (1) PDF downloads (1) Cited by()

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return