Processing math: 100%
    Advanced Search
    SHEN Jian-Min, QIU Fa-Ju, WANG Xiao-Hua. Eddy Current Testing of Austenitic Stainless Steel Heat Exchanger Tube[J]. Nondestructive Testing, 2008, 30(8): 547-549.
    Citation: SHEN Jian-Min, QIU Fa-Ju, WANG Xiao-Hua. Eddy Current Testing of Austenitic Stainless Steel Heat Exchanger Tube[J]. Nondestructive Testing, 2008, 30(8): 547-549.

    Eddy Current Testing of Austenitic Stainless Steel Heat Exchanger Tube

    More Information
    • Received Date: June 24, 2008
    • Double frequency method of conventional eddy current testing technology to inspect the austenitic stainless steel heat exchanger tube was introduced. It showed that the curve of phase against thickness decrease was greatly different from the stand curve in several kinds of literatures. The difference between the nature defect and artificial defect signals was compared, and the false defect signal excited by step-change of thickness in heat exchanger tube formed in manufacturing process was analyzed. Defect could be inspected by the assistant function(Altitude-Phase Warning). Through the analysis of the value of eddy current testing, it conclude that eddy current testing was in advantage of high speed, low prices, and being effect in inspecting the austenitic stainless steel heat exchanger tube.
    • [1]
      王海波,宋树波,邵泽波.涡流检测中探头运动速度对检测信号的影响分析J.吉林化工学院学报,2004,21(3):83-85.

    Catalog

      Article views (2) PDF downloads (1) Cited by()

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return