Advanced Search
    BI Qi, YANG Yu, YU Jun. Analysis on ID Tube Flaws Phase Angle above 40°[J]. Nondestructive Testing, 2011, 33(10): 62-63.
    Citation: BI Qi, YANG Yu, YU Jun. Analysis on ID Tube Flaws Phase Angle above 40°[J]. Nondestructive Testing, 2011, 33(10): 62-63.

    Analysis on ID Tube Flaws Phase Angle above 40°

    More Information
    • Received Date: March 10, 2011
    • Some ID flaws phase angle on secondary frequency channels is above 40° in tubes eddy current inspecting of the condenser. That is not matching with normal ID signal property. By experiments, we find that that is the axial ID flaws display. And the traditional depth curve of flaws should be corrected for more precision of the flaw evaluation.
    • [1]
      美国无损检测学会,编.美国无损检测手册·电磁卷[M].《美国无损检测手册》译审委员会,译.上海:世界图书出版公司,1999:207.
      [2]
      ASME锅炉及压力容器规范(2004版)第Ⅴ卷第8章附录Ⅰ[S].
      [3]
      JB/T 4730.6—2005承压设备无损检测第6部分:涡流检测[S].
      [4]
      刘一舟,曹刚,王晓翔.核电站钛管内壁缺陷判伤曲线[J].无损检测,2010,32(9):719-721.