Advanced Search
    YANG Shuqin, ZHONG Liying, ZHANG Yarong, ZHANG Jiarui, WANG Jinghai. Phased array ultrasonic testing for friction stir welding with weld thickness less than 6 mm[J]. Nondestructive Testing, 2020, 42(9): 17-20.
    Citation: YANG Shuqin, ZHONG Liying, ZHANG Yarong, ZHANG Jiarui, WANG Jinghai. Phased array ultrasonic testing for friction stir welding with weld thickness less than 6 mm[J]. Nondestructive Testing, 2020, 42(9): 17-20.

    Phased array ultrasonic testing for friction stir welding with weld thickness less than 6 mm

    More Information
    • Received Date: February 28, 2020
    • This paper introduces a phased array ultrasonic testing method for friction stir welding (FSW) with weld thickness less than 6 mm. Through a large number of tests and based on the actual test result data, the probe parameters, wedge block, scanning angle, scanning mode and display mode of phased array probe are explored, which has certain operability and can further improve the quality of detection. The method is convenient to operate and it can effectively save time and improve production. It is also capacity, safe and friendly to the environment and has high practical application value.
    • [1]
      冯聪. 开放式结构换热器管子管板焊缝氦检漏新型检测装置的应用[J]. 压力容器,2012,29(12):71-75.
      [2]
      丁训慎. 核电站蒸汽发生器制造和停堆期间的泄漏检验[J].无损检测,2009,31(2):159-161.
      [3]
      周胜. 氦检漏技术在核电站蒸发器传热管密封性试验中的应用[J].核科学与工程,2017,37(5):818-819.
      [4]
      吴孝检. 泄漏检测[M].北京:机械工业出版社,2005.

    Catalog

      Article views (5) PDF downloads (10) Cited by()

      /