Advanced Search
    ZHANG Ying-ying, HAN Wen-li, LI Ai-gui, SHAO Huai-qi, XIE Bei-bei. Study Progress of Cathodic Protection Current Shielding of Pipeline Coatings[J]. Corrosion & Protection, 2010, 31(10): 787-789.
    Citation: ZHANG Ying-ying, HAN Wen-li, LI Ai-gui, SHAO Huai-qi, XIE Bei-bei. Study Progress of Cathodic Protection Current Shielding of Pipeline Coatings[J]. Corrosion & Protection, 2010, 31(10): 787-789.

    Study Progress of Cathodic Protection Current Shielding of Pipeline Coatings

    More Information
    • Received Date: January 27, 2010
    • Combination of coatings with cathodic protection is the common measure to protect the pipelines from corrosion.But the shelled coating which has good insolation property may result in the current shielding for cathodic protection.This paper reviews the reasons of cathodic protection shielding of coatings,the forms of cathodic protection shielding,and its harm to the pipelines and the solution for the cathodic protection current shielding.
    • [1]
      Norsworthy R.Rating underground pipeline tape and shrink sleeve coating systems[J].Materials Performance,1999(11):40-46.
      [2]
      Norsworthy R.Coatings used in conjunction with cathodic protection-“Fail/Safe” pipeline coating systems[J].Materials Performance,2004(6):34-38.
      [3]
      Ruschau G R,Chen Y.Determining the CP shielding behavior of pipeline coatings in the laboratory[C]//Corrosion 2006,NACE International,Houston,Paper No.06043,4.
      [4]
      Kirby Drive.A review of gas industry pipeline coating practices[C]//Pipeline Research Council International,Published by Technical Toolboxes,Inc.,3801,Houston,1988:3-4.
      [5]
      Nunez S,Eastman A D,Babnick R J.Cathodic protection shielding definition[C]//AGA Corrosion Supervisory Committee,1989.
      [6]
      Neal D.Pipeline coating failure-not always what you think it is[C]//NACE Corrosion,2000,Paper 00755.
      [7]
      NACE Standard RP0169-2002.Control of external corrosion on underground or submerged metallic piping systems[C]//Houston TX:NACE International,77084-4906:4.
      [8]
      Argent C A,Norman D.Fitness for purpose issues relating to FBE and three layer PE coatings[R]//David Norman Corrosion Control,Cornwall,TR8 5SA,England.2005.
      [9]
      Michael Barker Jr.Inc.stress corrosion cracking stu-dy-final report[R]//USDOT OPS Delivery Order DTRS56-02-D-70036.2005.
      [10]
      Beavers J A,Thompson N G.External corrosion of oil and natural gas pipelines[C]//ASM Handbook,Volume 13C,Corrosion:Environments and Industries(#05145),ASM International,Materials Park,Ohio 44073-0002:1021.
      [11]
      Richard Norsworthy.Is your pipeline coating fail/safe[J].Pipeline & Gas Journal,2006(10):62-63.
      [12]
      郭兴蓬,张华民,殷朋.电流屏蔽效应和最佳阳极位置的确定[J].油田地面工程,1992,11(4):53-56.
      [13]
      刘玲莉,陈洪源,刘明辉,等.输油气站区阴极保护中的干扰与屏蔽[J].管道技术与设备,2005(2):31-33.
      [14]
      邱政权,冯洪臣,冯骅,等.管道阴极保护中的屏蔽问题[J].石油和化工设备,2006,9(2):38-40.

    Catalog

      Article views (4) PDF downloads (3) Cited by()

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return