Advanced Search
    LU Jun-dong, LIN Gen-xian, LIU Bin. Electrochemical Study on Several Inhibitors for A106 Carbon Steel in Deionized Water[J]. Corrosion & Protection, 2008, 29(7): 381-384.
    Citation: LU Jun-dong, LIN Gen-xian, LIU Bin. Electrochemical Study on Several Inhibitors for A106 Carbon Steel in Deionized Water[J]. Corrosion & Protection, 2008, 29(7): 381-384.

    Electrochemical Study on Several Inhibitors for A106 Carbon Steel in Deionized Water

    More Information
    • Received Date: July 17, 2007
    • The corrosion inhibition efficiency of several inhibitors for carbon steel in deionized water was evaluated by weight-loss measurements and polarization tests.The results showed that the inhibitor A had higher efficiency and was more persistent than the others in the temperatures range from 30 ℃ to 85 ℃,and the inhibition efficiency of the inhibitor was more than 95%.
    • [1]
      郑逸云,周柏青,李 芹,等.水处理缓蚀剂应用现状与发展[J].腐蚀科学与防护技术,2004,16(2):101-104.
      [2]
      刘 景,包伯荣,解 群,等.DP-1型缓蚀剂抑制硫离子对304不锈钢的侵蚀作用[J].腐蚀与防护,2005,26(6):231-233.
      [3]
      陈立庄,高延敏,缪文桦.有机缓蚀剂和金属作用的机理[J].全面腐蚀控制,2005,19(2):25-28.
      [4]
      张天胜.缓蚀剂[M].北京:化学工业出版社,1987.

    Catalog

      Article views (1) PDF downloads (2) Cited by()

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return