Advanced Search
    LI Min, LIAN Xiao-wen, LIANG Xu-xia, WANG Jing. On the Elimination of Interference of Calcium in the ICP-MS Determination of Iron with Low Concentration in Water[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2012, 48(7): 815-817.
    Citation: LI Min, LIAN Xiao-wen, LIANG Xu-xia, WANG Jing. On the Elimination of Interference of Calcium in the ICP-MS Determination of Iron with Low Concentration in Water[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2012, 48(7): 815-817.

    On the Elimination of Interference of Calcium in the ICP-MS Determination of Iron with Low Concentration in Water

    More Information
    • Received Date: July 11, 2011
    • It was found that the ICP-MS determination of cFe<0.06 mg·L-1 in water was interfered seriously by the presence of 40 mg·L-1 Ca2+. It was proved that the interference of Ca2+ could be eliminated by either of the following ways: ① by using the collision cell, no interference by Ca2+ is observed, and either of the isotopes 56Fe or 57Fe can be used; ② in case of without using collision cell, the interfernce of Ca2+ is varied according to the mass concentrations of Fe(Ⅲ) and the co-existing Ca2+, i.e., (a) in case of cFe<0.10 mg·L-1 and cCa<1 mg·L-1, the interference can be neglected by using the isotope 57Fe; (b) when cFe<0.10 mg·L-1 and cCa>1 mg·L-1, the interference is significant by using either of the 2 istopes; (c) when cFe>0.10 mg·L-1 and cCa<5 mg·L-1, the interference can be neglected and either of the 2 isotopes can be used, and when cCa>5 mg·L-1, the interference can be eliminated only by using the isotope 56Fe.
    • [1]
      GB/T 5750.6-2010生活饮用水标准检验方法[S].
      [2]
      刘丽萍,张妮娜,张岚,等.电感耦合等离子体质谱法测定矿泉水中23种元素[J].质谱学报, 2005,26(1):27-31.
      [3]
      王小如.电感耦合等离子体质谱应用实例[M].北京:化学工业出版社, 2005:222.
      [4]
      田佩瑶,魏建荣,陈斌生,等.生活饮用水中铁的电感耦合等离子体质谱测定法干扰因素的研究[J].环境与健康, 2010,27(7):626-628.
      [5]
      顾妍丽,宋振威.ICP-MS法测定矿泉水中15种元素含量的不确定度分析[J].中国卫生检验杂志, 2010,20(9):2360-2362.
      [6]
      邓泽英,应月青,李京晶.应用电感耦合等离子体发射光谱法快速测定食品中的钙、铁、锌[J].中国卫生检验杂志, 2011,21(2):519-520.