    • Received Date: December 21, 2005
    • After been used for 3-4 months,the crucible had serious crack at the joint of the bottom and side closing to the outer flame.Its analyzed that the temperature gradient along cross section causes the crack.The outer surfaces temperature is too high,so that the stress in the process of austenization,and the surface losing carbon makes the intensity decrease,eventually,the crucible cracked.
    • [1]
      林慧国,林钢,吴静雯.袖珍世界钢号手册[M].北京:机械工业出版社,2003.
      [2]
      张洪济.热传导[M].北京:高等教育出版社,2003.
      [3]
      Jorgel L H.Understanding the micro structure of overheated carbon steel[J].Materials Performance,2004,60(11):1095-1100.
      [4]
      魏成富,王学前.过冷奥氏体的异常分解与碳化物粒化[J].热加工工艺,1999,(2):21-27.
      [5]
      徐恒钧.材料科学基础[M].北京:北京工业大学出版社,2001.
      [6]
      夏立芳.金属热处理工艺学[M].哈尔滨:哈尔滨工业大学出版社,1996.