Advanced Search
    XU Yu-yu, ZHOU Jin-fan, WANG Hui, WANG Guo-xin, WU Cheng, ZHU Yu-yan, YU Lu. Detemination of Distribution Coefficients of Iron and Rare Earth Elements on DOWEX 1-X8 Anion Exchange Resin and Its Application to ICP-AES Determination of Rare Earth Elements in Steel[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2010, 46(4): 386-389.
    Citation: XU Yu-yu, ZHOU Jin-fan, WANG Hui, WANG Guo-xin, WU Cheng, ZHU Yu-yan, YU Lu. Detemination of Distribution Coefficients of Iron and Rare Earth Elements on DOWEX 1-X8 Anion Exchange Resin and Its Application to ICP-AES Determination of Rare Earth Elements in Steel[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2010, 46(4): 386-389.

    Detemination of Distribution Coefficients of Iron and Rare Earth Elements on DOWEX 1-X8 Anion Exchange Resin and Its Application to ICP-AES Determination of Rare Earth Elements in Steel

    More Information
    • Received Date: January 24, 2009
    • The distribution coefficients (Kd) of Fe3+ ion and ions of rare earth elements on DOWEX 1-X8 anion exchange resin in hydrochloric acid or nitric acid solutions of different acidites were studied.It was found that in 6-9 mol·L-1 hydrochloric acid,the Kd of Fe3+ was more than 103,while the Kd of rare earth elements were equal to or less than 10,hence,Fe3+ was adsorbed strongly on the resin,and ions of rare earth elements were not.The Kd of Fe3+ was less than 6.4 in nitric acid solution of concentration less than 2 mol·L-1,so Fe3+ was eluted from resin with 1.6 mol·L-1 nitric acid as eluent.Based on these facts,a method for separation of rare earth elements from matrix of iron was proposed and applied to the ICP-AES determination of rare earth elements in clean steels.Samples of clean steel produced in Japan and Korea were analyzed by the proposed method,giving values of recovery in the range of 87.7%-118.3%,and values of RSD′s (n=6) less than 23%.
    • [1]
      YOSHIHIDE E,KEIJI S,YUKI N.Determination of Al,Ce,La,Nb and Zr in steel by using optical emission spectrometry with an inductively coupled plasma[J].Journal of the Iron and Steel Institute of Japan,1978,64(6):797-803.
      [2]
      VASILI K K,ALEXANDER N T,HEINZ M K,et al.Extraction chromatographic separation of Y,REE,Bi,Th,and U from the matrix suitable for their determination in pure Iron and low-alloyed steels by ICP-MS and ICP-AES[J].Mikrochimica Acta,1998,130:47-54.
      [3]
      张亚杰,尹志辉.2-乙基己基膦酸单(2-乙基己基)酯树脂色层分离电感耦合等离子体原子发射光谱法测定钢中微量稀土元素[J].分析化学,1995,23(11):1288-1291.
      [4]
      AURORA G C,DORADO M T,PADILLA I,et al.Use of boric acid to improve the microwave-assisted dissolution process to determine fluoride forming elements in steels by flow injection inductively coupled plasma mass spectrometry[J].J Anal At Spectrom,1998,13:1193-1197.
      [5]
      AURORA G C,ISABEL P,TERESA D,et al.A micro-scale mercury cathode electrolysis procedure for on-line flow injection inductively coupled plasma mass spectrometry trace elements analysis in steel samples[J].Anal Chim Acta,1999,389:247-255.
      [6]
      DAVID B A,STANLEY J B,DAVID P B,et al.Houk,spatially-resolved analysis of solids by laser ablation-inductively coupled plasma-mass spectrometry: trace elemental quantification without matrix-matched solid standards[J].J Anal At Spectrum,2003,18:872-877.
      [7]
      JACKSON L L.Geological and inorganic materials[J].Anal Chem,1995,67(12):71-85.