高级检索

    碘量法测废水中硫化物的改进

    曾文超, 邵勇, 安立超, 刘广东

    曾文超, 邵勇, 安立超, 刘广东. 碘量法测废水中硫化物的改进[J]. 理化检验-化学分册, 2017, 53(1): 68-72. DOI: 10.11973/lhjy-hx201701014
    引用本文: 曾文超, 邵勇, 安立超, 刘广东. 碘量法测废水中硫化物的改进[J]. 理化检验-化学分册, 2017, 53(1): 68-72. DOI: 10.11973/lhjy-hx201701014
    ZENG Wen-chao, SHAO Yong, AN Li-chao, LIU Guang-dong. Improvement on Determination of Sulfide in Waste Water by Iodometry[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(1): 68-72. DOI: 10.11973/lhjy-hx201701014
    Citation: ZENG Wen-chao, SHAO Yong, AN Li-chao, LIU Guang-dong. Improvement on Determination of Sulfide in Waste Water by Iodometry[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(1): 68-72. DOI: 10.11973/lhjy-hx201701014

    碘量法测废水中硫化物的改进

    详细信息
      作者简介:

      曾文超(1991-),男,湖南娄底人,硕士,主要研究方向为废水处理与回用。

      通讯作者:

      安立超, E-mail:84315532@126.com

    • 中图分类号: O655.23

    Improvement on Determination of Sulfide in Waste Water by Iodometry

    • 摘要: 对碘量法测定废水中硫化物的标准方法(HJ/T 60-2000)中所述条件做进一步优化试验,提出了如下改进:① 选择水浴温度为65℃;② 吹氮的气体流量及时间:第1次为80 mL·min-1和20 min,第2次为300 mL·min-1和10 min,第3次为400 mL·min-1和6 min;③ 以1 mol·L-1乙酸锌溶液为吸收液,当样品中硫化物的质量浓度≤1.5 mg·L-1时,选择吸收液的加入量为3 mL;④ 方法适用于硫化物质量浓度在0.4~3 mg·L-1范围内的废水样品的分析;当实际质量浓度超过1.5 mg·L-1时,应减少取样量,使实际测定的试液中硫化钠的质量浓度保持在1.5 mg·L-1以内。按上述优化的条件,在实样的基础上作加标回收试验,测得回收率在94.4%~94.9%之间,测定值的相对标准偏差(n=6)在2.3%~3.4%之间。
      Abstract: Optimization for the conditions described in the standard method of iodometric determination of sulfides in waste water (HJ/T 60-2000) was made scrutinously, and the following modifications were given:① temperature of the water bath chosen:65℃; ② flow-rate and time of the 3 N2-blowings:80 mL·min-1 and 20 min for the 1st blowing, 300 mL·min-1 and 10 min for the 2nd blowing and 400 mL·min-1 and 6 min for the 3rd blowing; ③ 1 mol·L-1 zinc acetate solution was selected as absorbent, and 3 mL of the solution were used to absorb H2S liberated from the sample solution containing ≤1.5 mg·L-1 of sulfides; ④ the modified method was proved to be valid for samples containing sulfides in the range of 0.4-3 mg·L-1 and the portion of sample used for the determination should contain sulfides ≤1.5 mg·L-1. On the base of waste water samples as matrixes, test for recovery of the proposed method was made by standard addition method, results of recovery found were in the range from 94.4% to 94.9%, with values of RSDs (n=6) ranged from 2.3% to 3.4%.
    • [1] 乐江华.亚甲基蓝法测定油田污水中硫化物实验装置及条件的优化[J].中国化工贸易, 2013(9):236-236.
      [2] 刘洋,韩璐,宋永会,等.吹扫捕集-气相色谱联用同时测定水中致嗅挥发性有机硫化物[J].中国环境监测, 2014,30(1):144-149.
      [3]

      ZHANG K, DOU W, TANG X, et al. Selective and sensitive time-gated luminescence detection of hydrogen sulfide[J]. Tetrahedron Letters, 2015,56(21):2707-2709.

      [4] 王瑞斌,胡满成.硫化锌沉淀分离-EDTA滴定法测定废水中硫化物[J].冶金分析, 2008,28(9):71-73.
      [5] 朱金安,陈云祥.水中硫化物测定方法的研究[J].化工环保, 2000,20(1):39-43.
      [6] 于桂玲,赵凤芹,张彩霞,等.分光光度法测定水和废水中硫化物实验条件的优化选择[J].中国环境监测, 2004,20(1):29-33.
      [7]

      BALASUBRAMANIAN S, PUGALENTHI V. A comparative study of the determination of sulphide in tannery waste water by ion selective electrode (ISE) and iodimetry[J]. Water Research, 2000,34(17):4201-4206.

      [8]

      CAO X, XU H, DING S, et al. Electrochemical determination of sulfide in fruits using alizarin-reduced graphene oxide nanosheets modified electrode[J]. Food Chemistry, 2016,194:1224-1229.

      [9]

      HATTORI S, TOVODA A, TOYODA S, et al. Determination of the sulfur isotope ratio in carbonyl sulfide using gas chromatography/isotope ratio mass spectrometry on fragment ions 32S+, 33S+, and 34S+[J]. Analytical Chemistry, 2015,87(1):477-484.

      [10]

      XIANG K, LIU Y, LI C, et al. A colorimetric and ratiometric fluorescent probe with a large stokes shift for detection of hydrogen sulfide[J]. Dyes and Pigments, 2015,123:78-84.

      [11] 时巧翠.辣根过氧化物酶生物传感器检测硫化物的研究[J].分析试验室, 2010,29(6):75-78.
      [12] 王琳,李国强,张永发,等.硫化物测定时预处理方法的改进[J].工业水处理, 2013,33(11):79-81.
      [13] HJ/T 60-2000水质硫化物的测定碘量法[S].
      [14] 于红霞.影响水中硫化物测定的相关因素及注意事项[J].山东环境, 1999(4):35-35.
      [15] 王玉芝,于天霞,邢宇.加入EDTA改进硫化氢吸收液的方法探讨[J].化学与黏合, 2011,33(3):77-79.
      [16] 阿丽娅,钟琼,张红丽,等.硫化钠-锌铵溶液的稳定性[J].环境监测管理与技术, 2005,17(3):36-36.
      [17] 王娟.NaOH和乙酸锌-乙酸钠吸收液吸收废水中硫化物测定结果比较[J].新乡学院学报, 2010,27(6):41-42.
    计量
    • 文章访问数:  3
    • HTML全文浏览量:  0
    • PDF下载量:  0
    • 被引次数: 0
    出版历程
    • 收稿日期:  2016-01-17
    • 刊出日期:  2017-01-17

    目录

      /

      返回文章
      返回