Page 53 - 电力与能源2024年第六期
P. 53

第 45 卷 第 6 期                          电力与能源
                   2024 年 12 月                                                                          689

                                                                                       DOI:10.11973/dlyny202406013



                              上海并网发电厂 2023 年度发电锅炉


                                   “四管”泄漏失效分析与统计



                                         黄     诚 ,朱松鹤 ,谢             晶 ,陆      云   3
                                                             2
                                                  1
                                                                        2
                                       (1. 浙江浙能长兴天然气热电有限公司,浙江 长兴 313100;
                                       2. 华能国际股份有限公司上海石洞口第二电厂,上海 200940;
                                         3. 国网上海市电力公司电力科学研究院,上海 200437)


                    摘   要:分析了 2023 年度上海电网各并网发电厂发电锅炉“四管”泄漏失效的具体情况,列举了大量的现场案
                    例照片,并结合实验室检测数据进行泄漏原因分析,提出了相应的反措。同时对 2023 年度发电锅炉“四管”泄
                    漏原因和次数进行统计和比较,并为确保发电机组安全运行提出了建议。
                    关键词:并网电厂;发电锅炉;锅炉“四管”;泄漏失效
                    作者简介:黄      诚(1975—),男,工程师,从事火电生产管理工作。
                    中图分类号:TM73    文献标志码:A    文章编号:2095-1256(2024)06-0689-09
                    Analysis and Statistics of "Four Tubes" Leakage and Failure of Power Generation
                                 Boilers in Shanghai Grid-Connected Power Plants in 2023



                                                                  2
                                                                            2
                                                     1


                                       HUANG Cheng ,ZHU Songhe ,XIE Jing ,LU Yun     3

                  (1.Zhejiang Zheneng Changxing Natural Gas Cogeneration Co.,Ltd.,Changxing 313100,Zhejiang Province,China;




                      2.Huaneng International Power Co.,Ltd. Shanghai Shidongkou No.2 Power Plant,Shanghai 200940,China;



                  3. State Grid Shanghai Municipal Electric Power Company Electric Power Research Institute,Shanghai 200437,China)



                    Abstract:This paper summarizes the specific situations of "four tubes" leakage and failure of power generation
                    boilers in various grid-connected power plants in Shanghai power grid in 2023, lists a large number of on-site case
                    photos, conducts cause analysis in combination with laboratory material data, and puts forward corresponding cor⁃
                    rective measures. Moreover, it conducts statistics and comparisons on the causes and frequencies of "four tubes"
                    leakage of power generation boilers in 2023, and provides suggestions to ensure the safe operation of generator
                    sets.


                    Key words:grid-connected power plants,power generation boilers,"four tubes" of boilers,failure analysis


                    受电力需求增长以及能源转型的影响,上海                          压部件失效原因分析及故障、异常等缺陷处理和
                电网电力供应已从“紧平衡”转为“硬缺口”,十四                          跟踪管理。正是由于金属技术监督工作到位,及
                                                      “
                五”中后期上海电力保供面临严峻形势。2023 年                         时发现并处理了金属部件的缺陷隐患,避免了可
                度各并网电厂始终贯彻“安全第一,预防为主”的                           能发生的设备事故,减少了因金属部件失效造成
                电力生产方针,严格执行国家和行业有关金属技                            的机组“非停”事件。
                术监督标准、规范和反措,强化金属技术监督管                                截至 2023年底,上海电网内共有统调发电厂 70
                理;提高专业技术人员的业务水平,增强金属监督                           座,统调装机容量为 26 176.6 MW,其中 1 000 MW
                意识;做好受监金属部件的检验检测,做到不失                            机组 4 台、900 MW 机组 2 台、600 MW 级(含 650/
                监、不漏监、不误监;着重做好锅炉“四管”爆泄、承                         660 MW)机 组 7 台 、300 MW 级(包 括 300~480
   48   49   50   51   52   53   54   55   56   57   58